Replace the hot end on a Max4
Two screws, two plugs, swap the hot end, then check the wiper
- Printer QIDI Max4
- Steps 26
- Video 1:34
For a broken, leaking or worn-out hot end. About 45 minutes plus a test print. QIDI's steps from their video, written out so you can tick them off, with my own checks at the end. Mine snapped during the automatic nozzle wipe, so don't skip the wiper check. Each step's Show me button plays just that part of the video.
On the bench
- Hex keys from the printer's tool kit
- Flush cutters
- A new cable tie
- Tweezers and a torch
- Thermal grease (in the accessory box)
- Your phone, for a before photo
- A small dish or numbered screw tray, so the 2 hot end screws don't roll away
Steps
Progress
0 of 26 steps
Get it ready
Take the old one out
Undo the 2 hot end screws
Undo the 2 hot end screws with a hex key: the two on the front of the black finned heatsink (highlighted).
Note Leave the hot end in place. Its two cables are still plugged in. The plugs are behind the back cover, held by a cable tie you’ll cut in a moment, so have a spare tie ready.Check nothing is left behind My note
Shine a torch into the opening. If a broken bit of hot end or filament is stuck in there, ease it out with tweezers. If filament is jammed up in the extruder, do Clear a clogged Max4 extruder first.
Put the new one in
Thermal grease if it's dry My note
If the new hot end’s contact face looks dry, put a thin smear of thermal grease on it. Heat dries it out over time.Fit a new cable tie My note
Tie the cables back where the old tie was, so nothing rubs or hangs into the fan.
Stop the wipe snapping it
Check the nozzle wiper My note
Look at the nozzle wiper at the back of the bed. If its flexible part is bent, cracked or loose, swap in a spare. It should sit straight with its screw tight.Sock on, tip clean My note
Check the silicone sock is fully on and the nozzle tip has no blob of plastic. A hard blob is what catches on the wiper.Slide it over the wiper by hand My note
With the power still off, move the toolhead by hand across the wiper. Nothing should catch or scrape.
Check it works
Turn on, read the temperature My note
Plug in and turn on. The hot end should read close to room temperature. An error or a silly number means a plug isn’t in: turn off and recheck.PID tune the heater My note
In Fluidd’s console, typePID_CALIBRATE HEATER=extruder TARGET=220. Wait about 5 minutes for it to finish, then typeSAVE_CONFIG(the printer restarts).Careful The nozzle heats to 220°C. Keep hands clear.
Watch the first wipe My note
Run auto levelling from the screen and stand next to it. This also resets the Z offset, which matters because a new hot end can sit a fraction higher or lower. If the toolhead jerks or scrapes at the wiper, stop it.Load filament, print something small My note
Load filament and print a small test. If the first layer is smooth and stuck down, you’re done.
All done. Nice work.
The whole video
QIDI's original, if you'd rather watch it straight through.
QIDI Max4 Hotend Replacement Guide on YouTube (1:34)
Sources
- QIDI Max4 Maintenance Manual QIDI Tech Nozzle torque (1.5 to 2.0 N·m, tightened hot) and the heat-resistant gloves warning.
- QIDI Max4 wiki: Load filament QIDI Tech
- QIDI Max4 Hotend Replacement Guide QIDI Tech, 3 February 2026 QIDI's official video for swapping the Max4 hot end. No narration: the steps come from its on-screen captions.