↓ Skip to main content

Replace the hot end on a Max4

Two screws, two plugs, swap the hot end, then check the wiper

  • Printer QIDI Max4
  • Steps 26
  • Video 1:34

For a broken, leaking or worn-out hot end. About 45 minutes plus a test print. QIDI's steps from their video, written out so you can tick them off, with my own checks at the end. Mine snapped during the automatic nozzle wipe, so don't skip the wiper check. Each step's Show me button plays just that part of the video.

On the bench
  • Hex keys from the printer's tool kit
  • Flush cutters
  • A new cable tie
  • Tweezers and a torch
  • Thermal grease (in the accessory box)
  • Your phone, for a before photo
  • A small dish or numbered screw tray, so the 2 hot end screws don't roll away

Steps

Progress 0 of 26 steps

Get it ready

  1. Unload the filament

    On the screen, open the filament menu and tap Unload.

    [11]at 0:02

  2. Take the filament off

    Pull the filament out of the printer.

    [11]at 0:09

  3. Turn the printer off

    Switch it off at the power switch, then unplug it. Take a photo of the toolhead so you know how it all went back.

    Careful The hot end stays hot for a while after power off. Let it cool before you touch it.

    [11]at 0:12

Take the old one out

  1. Take off the front cover

    Pull the front cover off the toolhead.

    [11]at 0:15

  2. Undo the 2 hot end screws

    Undo the 2 hot end screws with a hex key: the two on the front of the black finned heatsink (highlighted).
    The Max4 toolhead with the front cover off. The two screws on the front of the black finned heatsink, just above the heater block, are highlighted in yellow.
    Note Leave the hot end in place. Its two cables are still plugged in. The plugs are behind the back cover, held by a cable tie you’ll cut in a moment, so have a spare tie ready.

    [11]at 0:19

  3. Take off the back cover

    Slide off the cover on the back of the toolhead (the one with rows of holes). The hot end plugs are behind it.

    [11]at 0:29

  4. Cut the cable tie

    Snip the cable tie holding the hot end cables. Cut the tie, not a wire.

    [11]at 0:36

  5. Unplug the heater cable

    Disconnect the hot end’s heating cable. Pull on the plug, never the wire.

    [11]at 0:42

  6. Unplug the temperature sensor

    Disconnect the hot end temperature sensor cable.

    [11]at 0:48

  7. Pull the old hot end out

    Slide the hot end down and out of the toolhead.

    [11]at 0:53

  8. Check nothing is left behind My note

    Shine a torch into the opening. If a broken bit of hot end or filament is stuck in there, ease it out with tweezers. If filament is jammed up in the extruder, do Clear a clogged Max4 extruder first.

Put the new one in

  1. Thermal grease if it's dry My note

    If the new hot end’s contact face looks dry, put a thin smear of thermal grease on it. Heat dries it out over time.

    [9]

  2. Slide the new hot end in

    Push the new hot end up into the toolhead, with its cable clip facing outward.

    [11]at 0:59[12]

  3. Plug in the heater cable

    Reconnect the heating cable until it clicks.

    [11]at 1:06

  4. Plug in the temperature sensor

    Reconnect the hot end temperature sensor cable until it clicks.

    [11]at 1:11

  5. Fit a new cable tie My note

    Tie the cables back where the old tie was, so nothing rubs or hangs into the fan.
  6. Back cover on

    Slide the back cover back on.

    [11]at 1:15

  7. Do up the 2 hot end screws

    Refit the 2 hot end screws. Firm, but don’t force them.

    [11]at 1:20

  8. Front cover on

    Clip the front cover back on. Compare with your before photo.

    [11]at 1:26

Stop the wipe snapping it

  1. Check the nozzle wiper My note

    Look at the nozzle wiper at the back of the bed. If its flexible part is bent, cracked or loose, swap in a spare. It should sit straight with its screw tight.

    [13]

  2. Sock on, tip clean My note

    Check the silicone sock is fully on and the nozzle tip has no blob of plastic. A hard blob is what catches on the wiper.
  3. Slide it over the wiper by hand My note

    With the power still off, move the toolhead by hand across the wiper. Nothing should catch or scrape.

Check it works

  1. Turn on, read the temperature My note

    Plug in and turn on. The hot end should read close to room temperature. An error or a silly number means a plug isn’t in: turn off and recheck.
  2. PID tune the heater My note

    In Fluidd’s console, type PID_CALIBRATE HEATER=extruder TARGET=220. Wait about 5 minutes for it to finish, then type SAVE_CONFIG (the printer restarts).

    Careful The nozzle heats to 220°C. Keep hands clear.

    [14]

  3. Watch the first wipe My note

    Run auto levelling from the screen and stand next to it. This also resets the Z offset, which matters because a new hot end can sit a fraction higher or lower. If the toolhead jerks or scrapes at the wiper, stop it.
  4. Load filament, print something small My note

    Load filament and print a small test. If the first layer is smooth and stuck down, you’re done.

    [10]

The whole video

QIDI's original, if you'd rather watch it straight through.

QIDI Max4 Hotend Replacement Guide on YouTube (1:34)

Sources

  1. QIDI Max4 Maintenance Manual QIDI Tech Nozzle torque (1.5 to 2.0 N·m, tightened hot) and the heat-resistant gloves warning.
  2. QIDI Max4 wiki: Load filament QIDI Tech
  3. QIDI Max4 Hotend Replacement Guide QIDI Tech, 3 February 2026 QIDI's official video for swapping the Max4 hot end. No narration: the steps come from its on-screen captions.
  4. QIDI Max4 bimetal hot end (part page) QIDI Tech Fit the hot end with its cable clip facing outward.
  5. QIDI Max4 nozzle wiper, 5 pack (part page) QIDI Tech Spare nozzle wipers for when the old one is bent or cracked.
  6. Klipper G-Codes: PID_CALIBRATE Klipper Tune the heater after fitting a new hot end, then SAVE_CONFIG.

More fixes